Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13658163

- Product Categories
- Friendly Links
- home > Supply > Xuzhou hand air conditioning recovery prices, used air conditioning, refrigeration Sheng Erda
Information Name: | Xuzhou hand air conditioning recovery prices, used air conditioning, refrigeration Sheng Erda |
Published: | 2015-04-08 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | Household air conditioner How to choose an installation location, into and out of the outlet away from obstructions to ensure airflow blowing through the room can; 2, choose easy to exclude condensate, easy to connect the outdoor unit where; 3, away from heat, steam and flammable gases ; 4, the choice can withstand the weight of the indoor unit operation without increasing the noise and vibration of the place; 5, the indoor unit is installed to ensure compliance with requirements for installation dimensions; 6, to ensure enough space maintenance required to ensure that the indoor unit and the ground level than 200CM ; 7, away from televisions, stereos and other household appliances, where more than 1 meter; 8, the air filter is easy to pull out of place. Barrier 3, near the indoor unit can not hinder the unit into the wind, the wind; the outdoor unit 1, no image noise and exhaust airflow generated to where neighbors; 2, there is a well-ventilated place to ensure that the outdoor unit is well ventilated thing; 4, the installation location of the outdoor unit should bear the weight and vibration, and to carry out the installation work safety; 5, no flammable gases, corrosive gas leak. Cleaning the indoor unit - cleaning venetian blinds panel panel cleaning (only for VV, YV split wall unit) 1. Disconnect the power Xuzhou hand air conditioning parts, unplug it. 2. Using both hands, grasp the panel blinds, horizontal lift and hold the hinged department pulled forward. Note: (1) Do not force the panel drawn blinds, panel blinds do not fall to the ground, Xuzhou used central air conditioning parts, so as to avoid the panel damage. (2) Do not stand unsteady table removable louvered panels, or they may tip over injuries. 3. Wipe with a soft cloth or washed, washed clean and dry with a soft cloth. Note: (1) remain in the water should be the opposite of the display unit with a soft, dry cloth. (2) stubborn stains with a soft cloth dipped in a neutral detergent. (3) Do not use gasoline, naphtha, solvent mixture, rubbing powder, disinfectant and detergent, do not wash with a brush or scouring pad contact surfaces like hard tool. (4) Do not for a long time (more than two hours) placed in direct sunlight and heating hot water or placed in scope, otherwise it will cause the front panel deformation and discoloration. Louver panel installation (for VV, YV split wall machines only) 1. Hold both ends of the louver panel with both hands, so that the panel louvers horizontal position. 2. The indoor unit hinge portion into the uppermost slot. (Insert clasp around until you hear the "click" is heard) 3. Using both hands, both ends of the louver panel and close the blinds panel. 4. Press the three parts and then hand the figure represented louver panel installed. Automatically shut down when the air conditioning and refrigeration is usually caused due to air conditioning overheating protection, overheating protection situation there are many, the main points of normal and non-normal, normal is when the air conditioning work in very harsh conditions, Xuzhou hand air conditioning installation, such as a very high ambient temperature refrigeration , press the load is too protective. Abnormal main system problems, such as lack of freon, and pipe blocked, the fan does not turn the other second-hand air conditioning, to determine the specific circumstances. Automatically shut down when the air conditioning refrigeration mainly: 1, built-in air conditioning electrical parts protection. Mainly air motors and compressors. Typically built on top of the compressor, is recoverable. When the temperature is too high, when turned off, the temperature is normal after recovery. 2, on the protection of air-conditioning control, generally there are several: 1) current protection, air conditioning control panel has detected press current exceeds a set value protection. 2) pressure protection, a lot of air conditioning has low pressure switch over to protect the value of protection. 3) thermal protection, air generally has a temperature sensor to protect the compressor, compressor discharge temperature is generally detected or compressor top temperature. Over protection value protection. Xuzhou hand air conditioning recovery prices, used air conditioning, refrigeration provided by Xuzhou Sheng Erda 圣尔达 Refrigeration Electrical Services Limited. Xuzhou 圣尔达 Refrigeration Electrical Services Limited (xzktw.com) strong, credible, in Xuzhou heat exchangers, refrigeration and air conditioning equipment industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving innovative ideas will lead Sheng Erda refrigeration and you hand into the brilliant, for a better future! |
Admin>>>
You are the 25475 visitor
Copyright © GuangDong ICP No. 10089450, Xuzhou Sheng Erda Refrigeration Electrical Services Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 25475 visitor
Copyright © GuangDong ICP No. 10089450, Xuzhou Sheng Erda Refrigeration Electrical Services Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility