Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13658163

- Product Categories
- Friendly Links
- home > Supply > Central air conditioning, refrigeration Sheng Erda, Xuzhou home central air conditioning prices
Information Name: | Central air conditioning, refrigeration Sheng Erda, Xuzhou home central air conditioning prices |
Published: | 2015-05-25 |
Validity: | 0 |
Specifications: | Any |
Quantity: | |
Price Description: | |
Detailed Product Description: | Chunlan air-conditioner compressor will not start to detect Chunlan radiator is not caused by too much dust and affect the cooling effect of Xuzhou central air conditioning maintenance, resulting in overheating Chunlan maintenance. Indeed maintain that overheating can be cleaned in time to remove the radiator fault. Chunlan Chunlan compressor heat maintenance resulting not start: ① Chunlan radiator excessive dust, causing the compressor to maintain not to launch; time to Chunlan radiator cleaning. ② Chunlan maintenance overheat damage; repair or replace your technical staff. 2, voltage doubt: ① voltage is too low or abnormal voltage peak period; ② Chunlan disconnect the power plug or power cord is damaged; timely replacement. ③ Chunlan Air Conditioner is not energized or indoor unit and outdoor unit cohesion circuit breaker; timely view sweep. 3, Chunlan maintenance overload damage; view sweep. 4, Chunlan capacitor or compressor fault cause Chunlan compressor will not start: ① Chunlan capacitor or compressor damage; repair or replace. ② compressor cylinder or seizures resulting card will not start; indoor air outlet temperature is too high (heating) troubleshooting method, check the air conditioning duct system is the presence of fouling of central air-conditioning renovation Xuzhou, if there is a corresponding adjustment is performed; 2, check the air conditioning electric auxiliary heat is abnormal working Xuzhou central air conditioning maintenance, namely air conditioning evaporator temperature sensor is high or is always on central air conditioning, if then the electric auxiliary heat control system failure, the need to check the air conditioning circuit boards; air conditioners frequently open 1. Stop the problem: too much fouling drain pan, drain clogging answer: Clear water tray, open the drain hole 2. Question: condensate drain bend or squash Answer: Check the drain, replace damaged new central air-conditioning, refrigeration Sheng Erda, Xuzhou home central air conditioning prices provided by Xuzhou 圣尔达 Refrigeration Electrical Services Limited. Xuzhou 圣尔达 Refrigeration Electrical Services Limited (xzktw.com) strong, credible, Xuzhou in Jiangsu Province of heat, refrigeration and air conditioning equipment industry has accumulated a large number of loyal customers. The company better work attitude and constantly improving innovative ideas will lead Sheng Erda refrigeration into the brilliant and you work for a better future! |
Admin>>>
You are the 25475 visitor
Copyright © GuangDong ICP No. 10089450, Xuzhou Sheng Erda Refrigeration Electrical Services Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 25475 visitor
Copyright © GuangDong ICP No. 10089450, Xuzhou Sheng Erda Refrigeration Electrical Services Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility